Operation
2.3.2 Pump with Three-Phase AC Motor
TRIVAC-B pumps with a three-phase motor are supplied
without accessories for electrical connection. They must
be connected via the appropriate cable, and a suitable
motor protection switch. Set the switch in accordance
with the rating on the motor nameplate.
Fig. 8 shows the connection for pumps with 230/400 V,
50 Hz motors. Please also observe the motor wiring dia-
gram in the junction box and the information given on the
nameplate of the motor.
After connecting the motor and after every
time you alter the wiring, check the direction
of rotation. To do so, briefly switch on the
motor and check whether a suitable cover
(e. g. a blank flange) is sucked on at the
intake port. If not, interchange two phases
of the connection.
Observe the direction arrow on the coupling
housing.
2.4 Start-up
Each time before starting up ensure that the oil level is
visible in the oil level glass.
For pumps with 3-phase motors, check the direction of
rotation before starting the pump for the first time and
after each change in the electrical connection (see Sec-
tion 2.3.2).
On initial start-up, after prolonged idle periods or after an
oil change, the specified ultimate pressure cannot be
attained until the oil is degassed. This can be done by
running the pump for approx. 30 min. with the intake line
closed and the gas ballast valve (7/5) open.
Before starting the pump ensure that the
pump and the fitted accessories meet the
requirements of your application and that
safe operation can be guaranteed.
Avoid exposure of any part of the body to
the vacuum. There is the danger of injury.
Never operate the pump with an open inta-
ke port. Vacuum connections as well as oil-
fill and oil-drain openings must never be
opened during operation.
The safety regulations which apply to the
application in each case must be observed.
This applies to installation, operation and
during maintenance (service) as well as
waste disposal and transportation.
The standard pump is not suited for pum-
ping of hazardous gases or vapours.
Our technical sales department is available for further
advice in these matters.
11
GA 01.202/9.02 - 03/96
Attention
Fig. 8 Connection diagram for TRIVAC-B with 50 Hz 3-phase motor
Delta connection
Star connection
Caution