Installation Instructions26
width of at least 3 mm.
Suitable isolation devices include line protecting cut-outs, fuses (screw type fus-
es are to be removed from the holder), earth leakage trips and contactors.
Sticking the seal in the rabbet
Clean the rabbet in the work surface.
Stick the one-sided self-adhesive sealing tape supplied onto the upper surface
of the rabbet along the edges of the cut-out section.
Cut the sealing tape into four pieces relating to the length of the edges of
the rabbet.
For the four corners of the rabbet the ends of the sealing tapes must be cut
into mitres. Do not stick the ends over one another.
Stick the sealing tape flush into the corner of the rabbet, so that no silicon
compound can get under the glass ceramic when grouting.
Don’t stretch the tapes when sticking them on.