- 10 -
DGS-TDS-N 12.08 U. H. / A. B. © Electrolux 599 714 137 EN
4.4 Error Codes induction hobs
Remark for hobs with left and right interface:
If a Error occurs the hob switches off automatically. Switch the hob on again the error is
displayed again. Afterwards the Error disaapears and the defect side is shown by the displays
“?” for bargraph or “E” in the 7-segment displayes.
4.5 Error Codes for cooking hobs with radiant heating
Error in the
timer display
Failure Solution for 5-zone induction
E0 Configuration Error of
Interface
Exchange Interfaces
E1 Compatibilty failure Exchange Interfaces
E2 n/a -
E3 Overvoltage; wrong
connection
Check power supply
E4 Temperature sensor coil
defect
The zone with the defect sensor
displays “E” or “?
”
Change the Coil of the displayed
zone
E5 Supply voltage out of range 1. Check Voltage and
Frequency
2. Exchange module left side
E6 Induction module defect Change module left with power
supply
“E7” in Timer display +
“E” or “?
”in the left zones
Change induction module on the
left side
E7
“E7” in Timer display +
“E” or “?
”in the right zones
Change iduction module on the
right side
E8 Communication error with
the power board
1. Check supply connection
2. Check wiring between
interface and power
board
3. Change induction module
E9 Internal interface error Exchange interface with silicone
carrier
Error in the
timer display
Failure Solution
E0 Configuration Error of
Interface
Exchange Interfaces
E1 Compatibilty failure Exchange Interfaces
E2 Pot detection error If pot detection is available
change Pot detection electronic
E3 n/a -
E4 n/a -
E5 Supply voltage out of range,
one phase missing
1. Check Voltage and
Frequency
2. Exchange module right side
E6 Induction module defect Change module left with power
supply
E7 “E7” in Timer display +
“E” or “?
”in the left zone
Exchange displayed heater with
pot detection senor and calibrate
new
E8 Communication error with
the power board
1. Check supply connection
2. Check wiring between
interface and power board
3. Change induction module
E9 Internal interface error
Liquid blocks interface
Exchange interface with silicone
carrier
Comentarios a estos manuales